APA to IEEE: Turning Author-Date References Into Numbers
APA 7th edition and IEEE could hardly be further apart: one cites by author and year, the other by number, and nothing in an APA entry says which number its work should get. An APA to IEEE conversion is two jobs at once — restyle every entry, then number the list in first-citation order. This guide shows it on one real article, explains how the converter reads APA text, and covers the renumbering that has to happen last.
Last updated:
Don't want to reformat by hand? Paste your references into the converter and get a formatted result — processed entirely in your browser.
Convert an APA list to IEEEAPA to IEEE: one article, two entries
Here is the same article in both systems. APA 7th edition: `LeCun, Y., Bengio, Y., & Hinton, G. (2015). Deep learning. Nature, 521(7553), 436–444.` IEEE: `[1] Y. LeCun, Y. Bengio, and G. Hinton, “Deep learning,” Nature, 521(7553), pp. 436–444, 2015.` Both are the Deep learning paper by LeCun, Bengio and Hinton, published in Nature in 2015, volume 521, issue 7553, pages 436–444, DOI 10.1038/nature14539. Every row in the table below is visible in that pair.
That IEEE entry is exactly what the converter produces from the pasted APA text. One detail deserves a second look: the volume and issue stay together as 521(7553), exactly as the APA text wrote them, because the parser folds them into the journal field as a single string. Convert the same paper from its DOI or from BibTeX, where volume and issue are separate fields, and the entry renders in the full IEEE shape: `[1] Y. LeCun, Y. Bengio, and G. Hinton, “Deep learning,” Nature, vol. 521, no. 7553, pp. 436–444, 2015, doi: 10.1038/nature14539.`
| Element | APA 7th edition | IEEE |
|---|---|---|
| In-text marker | (LeCun et al., 2015) | [1] |
| Authors | LeCun, Y., Bengio, Y., & Hinton, G. | Y. LeCun, Y. Bengio, and G. Hinton |
| Year | In parentheses after the authors | Near the end, before the DOI |
| Title | Sentence case, no quotation marks | Sentence case, in double quotation marks |
| Journal | In italics | In italics |
| Volume, issue | 521(7553) | vol. 521, no. 7553 (full record) |
| Pages | 436–444, no prefix | pp. 436–444 |
| DOI | Resolver URL: https://doi.org/10.1038/nature14539 | doi: 10.1038/nature14539 (full record only) |
| List order | Alphabetical by author | Order of first citation |
How the converter reads APA text
The converter does not edit the APA string: it parses it into a structured record — authors, year, title, journal, volume, issue and pages — and renders that record in IEEE. The parser expects the APA shape: an author block, a year in parentheses, a period, then the title up to its first period, then journal, volume, issue and pages.
Paste one reference per block, separated by a blank line, and paste them in the order they are first cited in your text. The parser splits the input on blank lines, and the converter numbers the list in pasted order — so the order you paste is the numbering you get. Only APA text parses this way: MLA, Harvard, Chicago and IEEE text cannot be used as input, because none of them puts the year in parentheses directly after the author block.
- Paste APA text, one reference per block, in citation order.
- Check the author block first: surname, comma, initials, then (year).
- Fix missing volume, issue or pages in the pasted text before converting.
- Renumbering belongs in the last pass, after the text stops changing.
Numbers replace names: citation order, not alphabetical
IEEE numbers entries in the order they are first cited: the first work cited is [1], the second [2], and the list is printed in that order. An APA to IEEE conversion therefore cannot keep the APA list's alphabetical order — its first entry becomes [1] only if it is also the first work cited. Paste in citation order, or renumber afterwards.
The marker in the text is the number in square brackets: `... as shown in [1].` The same work cited twice keeps the same number, and a range is written [1]–[3]. There is no author-date marker anywhere in IEEE, so (LeCun et al., 2015) never appears. Insert one source in paragraph two and every later number shifts by one, which is why numbering belongs in your last pass over the manuscript.
- Paste references in the order they are first cited.
- Cite with [1], not with the author name or year.
- Renumber after any insertion, since a new [2] shifts every later reference.
- The same work always keeps the same number.
Authors, titles and pages in IEEE
Author names flip order: APA writes surname first with initials after it, `LeCun, Y.`, while IEEE writes initials first, `Y. LeCun`. IEEE lists up to six authors in full; a longer list collapses to the first author plus et al. — a four-author record renders with all four names, while the eight-author Attention paper renders as `A. Vaswani et al.` The word before the last author is and, never an ampersand.
The title takes double quotation marks and stays in sentence case, “Deep learning,”, and the journal name is italicised. The year moves from directly after the authors to near the end of the entry, after the pages: `..., pp. 436–444, 2015.` The page range keeps its full length with a pp. prefix — IEEE does not shorten 436–444 to 436–44 the way MLA and Chicago do. The DOI, when the record has one, closes the entry as `doi: 10.1038/nature14539`, with a space after the colon.
What the parser drops, and how to keep it
The APA-text parser reads authors, year, title, journal, volume, issue and pages, and nothing else — there is no field for a DOI or a URL. So the IEEE entry above ends at the year, with no DOI; convert from the DOI or BibTeX for the doi: tail. A missing volume, issue or page range produces a short entry with no warning, so check the source text before converting.
Do not leave the DOI link on the end of the pasted text to keep it: with `https://doi.org/10.1038/nature14539` still attached, the parser misreads the tail — the journal field swallows the volume, pages and link, and the page range comes out as the last digits of the DOI. The mangled result renders as `[1] Y. LeCun, Y. Bengio, and G. Hinton, “Deep learning,” Nature, 521(7553), 436–444. https://doi.org/10.1038/nature14539, p. 14539, 2015.` Strip the link before pasting, and use a DOI lookup if the DOI must appear.
The converted list downloads as .bib, .ris or plain text, and the .ris file carries the records back into Zotero or EndNote. History keeps the most recent twenty items, or one hundred on Pro. Keep the .bib download too: a formatted string cannot be turned back into fields, while the .bib converts again for another style in seconds.
Frequently asked questions
Does converting renumber my references?
Why does my IEEE entry say 521(7553) instead of vol. 521, no. 7553?
Why is there no DOI in my IEEE entry?
How many authors does IEEE list?
Can I paste IEEE text back in as the input?
I inserted a reference in the middle — what now?
Convert an APA list to IEEE
Input BibTeX, APA text, a DOI or an arXiv link. Output APA, MLA, Chicago, Harvard, IEEE, BibTeX and GB/T 7714. Nothing is uploaded, no signup.
Convert the same list from BibTeX to IEEE